7.5.3. Removal and installation of the block of safety locks

Removal
Disconnect a weight wire from joint stock bank at the switched-off ignition.
Remove a ware compartment from the driver.

Fig. 7.88. Fastening of the block of safety locks


Unscrew screws of 1 block of safety locks of 2 (fig. 7.88).
Disconnect above and below clips and remove the block of safety locks from the central pipe of the forward panel.
Remove an electrical wiring plait from the central pipe of the forward panel and to release it from fastenings.
Make an incision Bender 1.

Fig. 7.89. Cover of the block of safety locks


Unblock a cover of the block of safety locks (arrow) (fig. 7.89).
Take safety locks from the block of safety locks.
Remove a fixing level of sockets (arrow) and pull out sockets from the block of safety locks.

Fig. 7.90. Extraction of sockets


Disconnect contact group 1 (fig. 7.90).

Installation
Establish in the return sequence.
Establish a ware compartment from the driver.
Connect the accumulator.

Inhaling moment
The block of safety locks to the central tube of the forward panel: 3 N · m.